Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
2.
Kyobu Geka ; 77(2): 101-105, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459858

RESUMO

A 75-year-old woman was diagnosed with type B acute aortic dissection 14 years ago and 3-channeled aortic dissection 7 years ago. She received total arch replacement 6 years ago and descending aortic replacement with double barrel anastomosis technique for distal anastomosis 5 years ago. Computed tomography( CT) revealed giant thyroid tumor and thoracoabdominal aortic aneurysm( 58 mm in diameter). She suffered from back pain during her follow-up period. CT revealed ruptured thoracoabdominal aortic aneurysm. First, the false lumen of descending aorta was closed by thoracic endovascular aortic repair, and then thoracoabdominal aortic replacement was performed uneventfully.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Dissecção Aórtica , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Feminino , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Anastomose Cirúrgica , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-38261486

RESUMO

We propose burst-wave-aided, contrast-enhanced, active Doppler ultrasonography for visualizing lymph vessels. This technique forces ultrasound contrast agents (UCAs) to move using the acoustic radiation force induced by burst waves with low amplitude while suppressing their destruction. Using a flow phantom, we measured the average, decrease rate of echo intensity [i.e., pulse intensity integral (PII)], and the velocity of individual contrast agents, which directly affects the performance of imaging and tracking contrast agents under stationary flow conditions. Comparison with pulse-inversion Doppler without exposure to the burst wave demonstrated that the velocity of the contrast agents could be enhanced up to several tens of millimeters per second by the effect of the burst wave, maximizing the echo intensity extracted by a clutter filter. The contrast ratio (CR), defined as the ratio of the contrast echo to the phantom echo outside the channel, did not change appreciably, even when the lower cut-off velocity of the clutter filter was increased up to 10 mm/s. This implies a better robustness against the motion of the tissue. In addition, the performance for detecting contrast agents (i.e., echo intensity) was superior or similar to that of pulse-inversion Doppler, even in undesirable conditions where the flow had a velocity component in the opposite direction to that of the acoustic radiation force. The echo intensity was lower or the same as that in pulse-inversion Doppler, demonstrating the potential for suppressing the destruction of contrast agents and enabling long-term observations. From these results, we expect that the proposed method will be beneficial for visualizing lymph vessels.


Assuntos
Meios de Contraste , Microbolhas , Ultrassonografia , Ultrassonografia Doppler/métodos , Angiografia , Imagens de Fantasmas , Velocidade do Fluxo Sanguíneo
4.
Ultrasound Med Biol ; 50(4): 592-599, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38238201

RESUMO

OBJECTIVE: Hepatic fibrosis has recently been evaluated using ultrasonography or magnetic resonance elastography. Although the shear wave velocity (SWV) obtained using point shear wave elastography (pSWE) provides a valuable measure of fibrosis, underlying steatosis may affect its measurement. METHODS: Using hepatic fibrosis samples, this study evaluated the effect of steatosis on the shear wave velocity of pSWE (Vs) and viscoelastic properties (assessed by dynamic mechanical analysis) of rat liver. Fifty rats with various grades of steatosis and fibrosis underwent open abdominal in vivo Vs measurements using a commercial ultrasound scanner. The mechanical properties of hepatic tissue were also characterized under ex vivo conditions using dynamic mechanical analysis and the Zener model of viscoelasticity. RESULTS: Fibrosis and steatosis progression influenced Vs and elasticity. The SWV computed using the Zener model and Vs showed a substantial correlation (r > 0.8). Fibrosis progression increased SWV. Steatosis was also related to SWV. Steatosis progression obscured the SWV change associated with fibrosis progression. CONCLUSION: We conclude that steatosis progression affects the evaluation of fibrosis progression. This finding could aid discrimination of non-alcoholic steatohepatitis from non-alcoholic fatty liver disease using SWV.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Ratos , Animais , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/complicações , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/complicações , Fibrose
5.
Vasc Endovascular Surg ; 58(3): 308-315, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37919942

RESUMO

OBJECTIVE: The optimal management strategy for patients with accessory renal arteries undergoing endovascular aortic repair is unclear. This study aimed to investigate the impact of accessory renal artery (aRA) embolization on postoperative renal deterioration and to identify the predictors of postoperative renal deterioration in patients who underwent endovascular aortic repair (EVAR). METHODS: A retrospective single-centre observational study was conducted at our hospital. Of 331 consecutive patients who underwent endovascular aortic repair between April 2011 and February 2021, 29 patients with an aRA were included in this study. Spearman's rank correlation coefficients of decrease in estimated glomerular filtration rate (eGFR), renal volume reduction rate, infarcted renal volume, and quantity of contrast use for postoperative renal deterioration were analyzed. The correlation coefficients of the correlations between infarcted renal volume, renal volume reduction rate, and decrease in eGFR and the rate of aRA diameter were also analyzed. Multivariable nominal logistic regression analyses were conducted to evaluate the odds of postoperative renal deterioration. RESULTS: The renal volume reduction rate and infarcted renal volume had a significant positive correlation with the decrease in eGFR. Body surface area and preoperative renal volume were significantly but negatively correlated with the decrease in eGFR. The infarcted renal volume, renal volume reduction rate, and decrease in eGFR were significantly and positively correlated with the aRA diameter. The odds ratio for decreased eGFR rate in preoperative renal volume was .96 (95% CI 0.930‒.996, P = .009). CONCLUSIONS: EVAR with aRA embolization impacts postoperative renal deterioration in patients with preoperative low renal volume, and the diameter of the embolized aRA might be a predictor of postoperative renal deterioration.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Nefropatias , Humanos , Correção Endovascular de Aneurisma , Artéria Renal/diagnóstico por imagem , Artéria Renal/cirurgia , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Risco
6.
J Med Ultrason (2001) ; 51(1): 5-16, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37796397

RESUMO

PURPOSE: Quantitative diagnosis of the degree of fibrosis progression is currently a focus of attention for fatty liver in nonalcoholic steatohepatitis (NASH). However, previous studies have focused on either lipid droplets or fibrotic tissue, and few have reported the evaluation of both in patients whose livers contain adipose and fibrous features. Our aim was to evaluate fibrosis tissue and lipid droplets in the liver. METHODS: We used an analytical method combining the multi-Rayleigh (MRA) model and a healthy liver structure filter (HLSF) as a technique for statistical analysis of the amplitude envelope to estimate fat and fibrotic volumes in clinical datasets with different degrees of fat and fibrosis progression. RESULTS: Fat mass was estimated based on the non-MRA fraction corresponding to the signal characteristics of aggregated lipid droplets. Non-MRA fraction has a positive correlation with fat mass and is effective for detecting moderate and severe fatty livers. Progression of fibrosis was estimated using MRA parameters in combination with the HLSF. The proposed method was used to extract non-healthy areas with characteristics of fibrotic tissue. Fibrosis in early fatty liver suggested the possibility of evaluation. On the other hand, fat was identified as a factor that reduced the accuracy of estimating fibrosis progression in moderate and severe fatty livers. CONCLUSION: The proposed method was used to simultaneously evaluate fat mass and fibrosis progression in early fatty liver, suggesting the possibility of quantitative evaluation for discriminating between lipid droplets and fibrous tissue in the early fatty liver.


Assuntos
Fígado , Hepatopatia Gordurosa não Alcoólica , Humanos , Progressão da Doença , Fígado/diagnóstico por imagem , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Ultrassonografia
7.
Kyobu Geka ; 76(11): 941-944, 2023 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-38056952

RESUMO

An 85-year-old woman underwent aortic arch replacement and thoracic endovascular aortic repair (TEVAR) 5 years ago. She suffered from chest and back pain. Computed tomography (CT) demonstrated enlargement of the aortic aneurysm by a type Ⅲb endoleak. TEVAR was performed to close a type Ⅲb endoleak with a relining technique uneventfully. Intraoperative completion aortography and postoperative CT confirmed the disappearance of a type Ⅲb endoleak. She was discharged 27 days after the treatment.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Feminino , Humanos , Idoso de 80 Anos ou mais , Prótese Vascular , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Correção Endovascular de Aneurisma , Stents , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos
8.
Kyobu Geka ; 76(12): 1025-1029, 2023 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-38057981

RESUMO

An 82-year-old woman suddenly developed chest pain and apoplexy. Computed tomography (CT) showed acute type A aortic dissection, the true lumen in the brachicephalic artery was severely compressed by the faulse lumen. Pulsation in the either leg was not detected during induction of anesthesia. We evaluated the cerebral blood flow and lower extremity blood flow using near infrared spectroscopy (NIRS) during the operation, tissue oxygenation index (TOI) was continuously monitored during the operation. Cardiopulmonary bypass( CPB) was established by puncturing the true lumen in the ascending aorta and bicaval venous drainage. TOI was returned to normal range by CPB. Although the central repair (ascending aorta replacement) was performed, leg ischemia persisted. We performed ascending aorta-bifemoral bypass. After the operation, leg ischemia disappeared and CT revealed patency of the bypass graft. Postoperative course was uneventful without deterioration of neurological function. She was discharged 49 days after the operation.


Assuntos
Dissecção Aórtica , Perna (Membro) , Feminino , Humanos , Idoso de 80 Anos ou mais , Perna (Membro)/irrigação sanguínea , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Isquemia/cirurgia , Extremidade Inferior/cirurgia
9.
Kyobu Geka ; 76(5): 371-374, 2023 May.
Artigo em Japonês | MEDLINE | ID: mdl-37150917

RESUMO

A 76-year-old man had been under observation for nephrotic syndrome. He suffered from hypotension and transient loss of consciousness. He was diagnosed with thoracic aortic aneurysm and severe aortic valve stenosis. Ascending aorta replacement concomitant with aortic valve replacement was performed uneventfully. He was diagnosed with light chain amyloidosis by pathological examination of the resected ascending aorta. He was received referral treatment for amyloidosis.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Estenose da Valva Aórtica , Masculino , Humanos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Aneurisma Aórtico/cirurgia , Aorta/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações
10.
Surg Case Rep ; 9(1): 83, 2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37199798

RESUMO

BACKGROUND: Azygos vein aneurysms are rare and asymptomatic in many cases. The management for these aneurysms is controversial, and there is no clear guideline or evidence-based threshold for surgical or interventional therapy. CASE PRESENTATION: Herein, we report the case of a giant azygos vein aneurysm in a 78-year-old man that was treated with a reversed L-shaped incision. A 56 × 77 mm saccular azygos vein aneurysm was incidentally detected on computed tomography. Subsequently, surgical resection with interventional radiology and reversed L-shaped thoracotomy was performed. First, we performed coil embolization of the azygos vein aneurysm inflow. Next, a cardiopulmonary bypass was established through a reversed L-shaped sternotomy, and the aneurysm was excised. CONCLUSIONS: In this case, surgical resection via reversed L incision was effective.

11.
Kyobu Geka ; 76(6): 481-485, 2023 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-37258030

RESUMO

A 59-year-old woman was transferred to our hospital because of a sudden onset of chest and back pain. Computed tomography (CT) demonstrated Stanford type A acute aortic dissection with cardiac tamponade and right airway bleeding. Hemorrhage from ruptured false lumen extended along the pulmonary artery (PA), compression of the right PA were recognized due to hematoma surrounding the PA. An emergency operation was performed. The primary tear was located at the distal aortic arch, and total arch replacement with frozen elephant trunk was performed. During the operation, she had airway bleeding. The bleeding was thought to be due to the hematoma extending along the pulmonary artery. She was extubated 7th postopratively. She was discharged 44 days after the operation.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Feminino , Humanos , Pessoa de Meia-Idade , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/cirurgia , Hematoma/cirurgia , Pulmão/cirurgia
12.
Kyobu Geka ; 76(3): 216-220, 2023 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-36861279

RESUMO

A 73-year-old man underwent drug eluting stent (DES) implantation in the left anterior descending artery (LAD) 11 years ago and in the right coronary artery (RCA) 8 years ago. He suffered from chest tightness and was diagnosed with severe aortic valve stenosis. Perioperative coronary angiography revealed no significant stenosis and thrombotic occlusion of the DES. Five days before operation, antiplatelet therapy was discontinued. Aortic valve replacement was performed uneventfully. But he developed chest pain and transient loss of consciousness, electrocardiographic changes were observed on the 8th postoperative day. Emergency coronary angiography revealed thrombotic occlusion of the drug eluting stent in the RCA, despite the postoperative oral adoministration of warfarin and aspirin. Percutaneous catheter intervention (PCI) restored the stent patency. Dual antiplatelet therapy (DAPT) was initiated immediately after the PCI, and anticoagulation therapy with warfarin was continued. Clinical symptons of stent thrombosis disappeared immediately after the PCI. He was discharged 7 days after the PCI.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Idoso , Valva Aórtica/cirurgia , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Varfarina , Período Perioperatório
13.
Kyobu Geka ; 76(2): 140-143, 2023 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-36731849

RESUMO

An 86-year-old woman who suffered from cardiac tamponade due to acute Stanford type A aortic dissection was admitted to our hospital. An emergency operation was performed uneventfully. She suffered from abdominal pain 13 days after the operation. Computed tomography( CT) scan revealed pericholecystic fluid and unclear gallbladder wall, revealing acalculous necrotizing cholecystitis. We performed open cholecystectomy and abdominal cavity drainage. No gallstones were observed. She underwent intensive treatment. She was discharged without complications 44 days after the cholecystectomy.


Assuntos
Dissecção Aórtica , Vesícula Biliar , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Necrose
14.
J Cardiothorac Surg ; 17(1): 308, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36517888

RESUMO

BACKGROUND: Clinically insignificant hemolytic anemia is occasionally a complication of prosthetic valve replacement. However, hemolysis related to kinked grafts is a very rare complication after central repair for acute aortic dissection. CASE PRESENTATION: A 42-year-old man had undergone replacement of the ascending aorta and a root repair for type A aortic dissection 6 months previously. Laboratory data showed mild hemolysis 5 months later, and he began to complain of fatigue on exertion. The serum hemoglobin level reduced to 8.6 g/dL, and lactate dehydrogenase levels increased to 3071 IU/L with gross change in urine color, indicating hemoglobinuria. We diagnosed mechanical hemolytic anemia caused by a kinked graft and planned a repeat operation. The kinked graft was resected and graft-graft anastomosis was performed. Postoperatively, the clinical course was uneventful, and the hemolytic anemia completely resolved. CONCLUSION: We herein report a case of hemolytic anemia caused by kinking of the graft 6 months after acute aortic dissection repair. The diagnosis was swiftly made, and the patient was successfully managed with redo surgery.


Assuntos
Anemia Hemolítica , Dissecção Aórtica , Masculino , Humanos , Adulto , Hemólise , Dissecção Aórtica/cirurgia , Anemia Hemolítica/etiologia , Anemia Hemolítica/cirurgia , Aorta/cirurgia , Reoperação , Prótese Vascular/efeitos adversos
15.
Kyobu Geka ; 75(13): 1103-1107, 2022 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-36539227

RESUMO

A 78-years-old woman was referred to our institution for the treatment of right subclavian artery (SCA) aneurysm. She previously underwent total arch replacement via median sternotomy approach. Preoperative computed tomography revealed a 55 mm sized SCA aneurysm. Stent graft was inserted from brachiocephalic artery to right common carotid artery via the graft anastomosed. The orifice of the right SCA was covered with stent graft inserted into the right common carotid artery-brachiocephalic artery and the right SCA was occluded with coils distal to the aneurysm, carotid-SCA bypass was performed with 8 mm ePTFE graft. Postoperative examination confirmed complete exclusion of the aneurysm and patency of the bypass graft. We thought that hybrid treatment for this patient was a less invasive alternative to conventional surgical procedure.


Assuntos
Aneurisma , Implante de Prótese Vascular , Feminino , Humanos , Idoso , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/cirurgia , Stents , Tomografia Computadorizada por Raios X , Implante de Prótese Vascular/métodos
16.
J Clin Med ; 11(3)2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35160327

RESUMO

During the COVID-19 pandemic, intravitreal injections are performed with patients wearing masks. The risk of endophthalmitis after intravitreal injection is reported to increase due to an influx of exhaled air containing oral bacteria from the upper part of the mask onto the ocular surface. We retrospectively investigated the incidence of endophthalmitis when intravitreal anti-vascular endothelial growth factor (anti-VEGF) injections were performed using the same infection control measures before and during the pandemic. Vitreoretinal specialists performed intravitreal injections of anti-VEGF agents in the outpatient room of a university hospital. Infection control measures before and during the pandemic included covering the patient's eye with adhesive face drape and irrigating the ocular surface with 0.25% povidone-iodine before draping, and immediately before and after injection. Before the COVID-19 pandemic (February 2016 to December 2019), one case of endophthalmitis occurred among 31,173 injections performed (0.0032%; 95% confidence interval (CI), 0.000008-0.017872%). During the COVID-19 pandemic (January 2020 to August 2021), one case of endophthalmitis occurred among 14,725 injections performed (0.0068%; 95% CI, 0.000017-0.037832%). There was no significant difference between the two periods (Fisher's exact test: p = 0.5387). Even during the COVID-19 pandemic, very low incidence of endophthalmitis after intravitreal injection can be maintained by implementing basic infection prophylactic measures, including face draping and 0.25% povidone-iodine irrigation, established before COVID-19 pandemic.

17.
Ultrasonics ; 118: 106580, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34555738

RESUMO

Recently, a method for estimating three-dimensional acoustic impedance profiles in cultured cells and human dermal organs was proposed by interpreting the reflected ultrasonic signal based on a 1-D transmission line model for acoustic impedance microscopy (AIM). However, AIM has a disadvantage that reflected signals from cells overlap with that from a reference substrate. Additionally, the amplitudes of the reflected signals from the specimens are significantly weaker than that from the substrate. In this paper, we proposed a new method for separation of those signals based on a concept of clutter filter, which had been developed for a color Doppler method in medical ultrasonic imaging. The proposed filter using singular value decomposition (SVD) could separate original signals into desired signals such as those from the substrate and cells. Additionally, an effect from a tilt of the substrate was investigated in this study. Separability of the proposed filter was evaluated by two investigations. First one was to evaluate the separability by estimating a correlation coefficient between the filtered signal and signal reflected from a position only with the substrate. Second one was to compare a slope of the substrate estimated from the original signal with that estimated from the filtered signals from the substrate. The experimental results showed that the proposed filter could separate signals from the substrate, and the compensation of the tilt of the substrate could improve the performance of the proposed filter.


Assuntos
Astrócitos/ultraestrutura , Células Cultivadas/ultraestrutura , Microscopia Acústica/instrumentação , Animais , Desenho de Equipamento , Ratos , Processamento de Sinais Assistido por Computador
18.
Am J Case Rep ; 22: e931796, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34059614

RESUMO

BACKGROUND Giant cell tumor of bone (GCTB) is a locally aggressive, intermediate tumor that rarely metastasizes. GCTB typically affects the ends of long bones and rarely involves the ribs. Curettage is typically the treatment of choice for GCTB in long bones. However, the optimal treatment of GCTB in ribs remains unclear. We report the case of a patient with asymptomatic GCTB of the first rib that was successfully treated with combined preoperative denosumab therapy and surgery via a transmanubrial approach without resection of the clavicle. CASE REPORT A healthy 27-year-old woman presented with a bone tumor involving the left first rib that was incidentally discovered on routine chest X-ray. Histological examination of core-needle biopsy specimens of the lesion led to a pathological diagnosis of GCTB. After preoperative denosumab treatment for 6 months, en bloc resection via a transmanubrial approach was performed. There were no serious postoperative complications. The patient remained free of symptoms and had no recurrence 4.5 years after surgery. CONCLUSIONS Compared with other ribs, masses located in the first rib can be challenging to treat surgically because of the clavicle and neighboring neurovascular structures. This report is the first to describe GCTB located on the anterior aspect of the first rib that was successfully treated with combined preoperative denosumab therapy and surgery via a transmanubrial approach, with no recurrence or functional impairment of the shoulder girdle.


Assuntos
Conservadores da Densidade Óssea , Tumor de Células Gigantes do Osso , Adulto , Denosumab/uso terapêutico , Feminino , Tumor de Células Gigantes do Osso/diagnóstico por imagem , Tumor de Células Gigantes do Osso/tratamento farmacológico , Tumor de Células Gigantes do Osso/cirurgia , Humanos , Recidiva Local de Neoplasia , Costelas/cirurgia
19.
J Acoust Soc Am ; 148(3): 1681, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-33003867

RESUMO

A better understanding of ultrasound scattering in a three-dimensional (3D) medium can provide more accurate methods for ultrasound tissue characterization. The possibility of using two-dimensional impedance maps (2DZMs) based on correlation coefficients has shown promise in the case of isotropic and sparse medium [Luchies and Oelze, J. Acoust. Soc. Am. 139, 1557-1564 (2016)]. The present study investigates the use of 2DZMs in order to quantify 3D scatterer properties of dense media from two-dimensional (2D) histological slices. Two 2DZM approaches were studied: one based on the correlation coefficient and the other based on the 2D Fourier transform of 2DZMs. Both 2DZM approaches consist in estimating the backscatter coefficient (BSC) from several 2DZMs, and then the resulting BSC was fit to the theoretical polydisperse structure factor model to yield 3D scatterer properties. Simulation studies were performed to evaluate the ability of both 2DZM approaches to quantify scattering of a 3D medium containing randomly distributed polydisperse spheres or monodisperse ellipsoids. Experimental studies were also performed using the histology photomicrographs obtained from HT29 cell pellet phantoms. Results demonstrate that the 2DZM Fourier transform-based approach was more suitable than the correlation coefficient-based approach for estimating scatterer properties when using a small number of 2DZMs.

20.
Diagnostics (Basel) ; 10(8)2020 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-32759867

RESUMO

Ultrasound imaging is a first-line assessment tool for hepatic steatosis. Properties of tissue microstructures correlate with the statistical distribution of ultrasound backscattered signals, which can be described by the Nakagami distribution (a widely adopted approximation of backscattered statistics). The double Nakagami distribution (DND) model, which combines two Nakagami distributions, was recently proposed for using high-frequency ultrasound to analyze backscattered statistics corresponding to lipid droplets in the fat-infiltrated liver. This study evaluated the clinical feasibility of the DND model in ultrasound parametric imaging of hepatic steatosis by conducting clinical experiments using low-frequency ultrasound dedicated to general abdominal examinations. A total of 204 patients were recruited, and ultrasound image raw data were acquired using a 3.5 MHz array transducer for DND parametric imaging using the sliding window technique. The DND parameters were compared with hepatic steatosis grades identified histologically. A receiver operating characteristic (ROC) curve analysis was used to evaluate the diagnostic performance. The results indicated that DND parametric imaging constructed using a sliding window with the side length of five times the pulse length of the transducer provided stable and reliable DND parameter estimations and visualized changes in the backscattered statistics caused by hepatic steatosis. The DND parameter increased with the hepatic steatosis grade. The areas under the ROC curve for identifying hepatic steatosis were 0.76 (≥mild), 0.81 (≥moderate), and 0.82 (≥severe). When using low-frequency ultrasound, DND imaging allows the clinical detection of hepatic steatosis and reflects information associated with lipid droplets in the fat-infiltrated liver.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...